List Of Labs - Equipment Ordering

ApchemWiki | RecentChanges | Preferences

Difference (from revision 3 to current revision) (minor diff)

Changed: 14,16c14,21
1. bunsen burner

2. crucible with cover

3. crucible tongs




Glassware

1. 50ml buret

2. 25ml volumetric flask

3. 50ml volumetric flask

3. 50ml Erlenmeyer flask

2. 250ml Erlenmeyer flask


Added: 17a23,33
3. 250ml beakers

5. 400ml beakers

6. 600ml beaker

6. 10ml graduated cylinder

6. 25ml graduated cylinder

6. 50ml graduated cylinders

7. Test tubes, small (13X100mm)

8. Test tubes, larger (18X150mm)

9. Test tube, largest (20X150m)



Disposable


Added: 18a35,39
6. 10ml disposable pipets

7. pH paper



Short term use equipment

2. crucible with cover


Added: 19a41,46
9. Thermometer



Long term use equipment

1. bunsen burner

3. crucible tongs

7. One hole cork for large brtest tubes


Added: 20a48,50
7. O rings

8. utility clamp

8. buret clamp


Added: 21a52,60
9. Hot plates



Vernier Probes

1. Temp probe

2. pH probes

3. Colorimeter probe/unit

2. Gas pressure probe (plastic tube with two Luer-lock connectors and rubber stopper assembly with two-way valve)

3. 20ml gas syringe

4. ORP probe (do not have cost $79 each)


Changed: 24,25c63,68
Laboratory :

1. Determination of the formula of a compound. (1.5hs)a







Laboratory :


1. Determination of the formula of a compound. (1.5hs)a


Changed: 28,29c71,72
2. Determination of the percentage of water in a hydrate (1hr)(a)

crucible with cover, crucible tongs. triangle, ring stand, bunsen burner, filter paper, 125ml Erylmeyer flask, funnel

2. Determination of the percentage of water in a hydrate (1hr)(a)

crucible with cover, crucible tongs. triangle, ring stand, bunsen burner, filter paper, 125ml Erylmeyer flask, funnel


Changed: 31c74,75
3. Determination of molar mass by vapor density (1.5hr)(b)
3. Determination of molar mass by vapor density (1.5hr)(b)

large test tube (13X100mm) and one hole cork, thermometer, 400ml beaker, hot plate

Changed: 33c77,78
4. Determination of molar mass by freezing-point depression (2hr)(a)
4. Determination of molar mass by freezing-point depression (2hr)(a)

Vernier temp probe, ring stand, utility clamp, 400ml beaker, largest test tube (18X150mm)


Changed: 35c80,81
5. Determination of molar volume of a gas. (2hr)(a)
5. Determination of molar volume of a gas. (2hr)(a)

Vernier temp probe, Vernier pressure probe (plastic tube with two Luer-lock connectors and rubber stopper assembly with two-way valve), 20ml gas syringe, 600ml beaker, 125ml Erlenmeyer flask


Changed: 37c83,84
6. Standardization of a solution using primary standard (2hr)(a)
6. Standardization of a solution using primary standard (2hr)(a)

Vernier pH probe, 50ml buret, 50ml graduated cylinder, 250ml beaker, disposable pipet (10ml)


Changed: 39c86,87
7. Determination of concentration by acid-base titration, including weak acid or weak base (2hr)(a,b)
7. Determination of concentration by acid-base titration, including weak acid or weak base (2hr)a,b

Vernier pH probe, 50ml buret, 50ml graduated cylinder, 250ml beaker, disposable pipet (10ml)


Changed: 41c89,90
8. Determination of concentration by oxidation-reduction titration (2hr)( c)
8. Determination of concentration by oxidation-reduction titration (2hr)c

25ml volumetric flask, 50ml buret, 250ml Erlenmeyer flask


Changed: 43,45c92,93
9. Determination of mass and mole relationship in a chemical reaction (2hr)(a)


10. Determination of the equilibrium constant for a chemical reaction (2hr)(a,b)
9. Determination of mass and mole relationship in a chemical reaction (2hr)a

Vernier temp probe, 10ml graduated cylinder, 25ml graduated cylinder, 50ml graduated cylinder, 250ml beaker


Changed: 47c95,96
11. Determination of appropriate indicators for various acid-base titration, pH determination (2hr)(a)
10. Determination of the equilibrium constant for a chemical reaction (2hr)a

Vernier colorimeter, 50ml volumetric flasks, 10ml disposable pipets, small test tubes (20X150mm), 100ml beakers


Changed: 49c98,99
12. Determination of the rate of a reaction and its order. (2hr)( c)
11. Determination of appropriate indicators for various acid-base titration, pH determination (2hr)a

Vernier pH probe, 250ml beaker, 50ml graduated cylinder, ring stand, buret clamp, 50ml buret


Changed: 51c101,102
13. Determination of enthalpy change associated with a reaction (2hr)( a)
12. Determination of the rate of a reaction and its order. (2hr)c

50ml Erlenmeyer flask, 10ml graduated cylinder, one-hole stopper attachment (see c for details)


Changed: 53c104,105
14. Separation and qualitative analysis of cations and anions. (3+hr)(b)
13. Determination of enthalpy change associated with a reaction (2hr)a

25ml graduated cylinder, beaker, styrofoam cups, thermometer


Changed: 55c107,108
15. Synthesis of a coordination compound and its chemical analysis (2+hr)(b)
14. Separation and qualitative analysis of cations and anions. (3+hr)b

test tubes, small (13X100mm), 10ml disposable pipets, pH paper


Changed: 57c110,111
16. Analytical gravimetric determination (1.5hr)(a,b)
15. Synthesis of a coordination compound and its chemical analysis (2+hr)(b)

??????


Changed: 59c113,115
17. Colorimetric or spectrophotometric analysis (2hr)(b)
16. Analytical gravimetric determination (1.5hr)(a,b)

????

17. Colorimetric or spectrophotometric analysis (2hr)(b)


Changed: 61c117
18. Separation by chromatography (2hr)( b,c)
18. Separation by chromatography (2hr)( b,c)


Changed: 63c119
19. Preparation and properties of buffer solutions (1.5hr)( b)
19. Preparation and properties of buffer solutions (1.5hr)b


Changed: 65c121
20. Determination of electrochemical series (1hr)(a,b)
20. Determination of electrochemical series (1hr)(a,b)


Changed: 67c123
21. Measurement using electrochemical cells and electroplating (1.5hr)(a, c)
21. Measurement using electrochemical cells and electroplating (1.5hr)(a, c)


Changed: 69c125,126
22. Sythesis, purification and analysis of an organic compound (2+hr)(b)
22. Sythnesis, purification and analysis of an organic compound (2+hr)(b)

test tube small (13X100mm), 250ml beaker, 400ml beaker, hot plate


Laboratory Manual:

We do not use one specific lab manual but rather a collection from various sources including:
a. Randall, Jack , Advanced Chemistry with Vernier, Vernier Software & Technology, (ISBN 1-929075-36-7 (alternate, search)).
b. Vonderbrink, Sally Ann, Laboratory Experiments for Advanced Placement Chemistry, (ISBN 1-877991-34-1 (alternate, search)).
c. Fossett, Martin and Hostage, David, AP Chemistry Laboratory Investigations.


General List

Glassware
1. 50ml buret
2. 25ml volumetric flask
3. 50ml volumetric flask
3. 50ml Erlenmeyer flask
2. 250ml Erlenmeyer flask
4. 125ml Erylmeyer flask
3. 250ml beakers
5. 400ml beakers
6. 600ml beaker
6. 10ml graduated cylinder
6. 25ml graduated cylinder
6. 50ml graduated cylinders
7. Test tubes, small (13X100mm)
8. Test tubes, larger (18X150mm)
9. Test tube, largest (20X150m)

Disposable
5. filter paper
6. 10ml disposable pipets
7. pH paper

Short term use equipment
2. crucible with cover
6. funnel
9. Thermometer

Long term use equipment
1. bunsen burner
3. crucible tongs
7. One hole cork for large brtest tubes
7. Ring stands
7. O rings
8. utility clamp
8. buret clamp
8. Triangle
9. Hot plates

Vernier Probes
1. Temp probe
2. pH probes
3. Colorimeter probe/unit
2. Gas pressure probe (plastic tube with two Luer-lock connectors and rubber stopper assembly with two-way valve)
3. 20ml gas syringe
4. ORP probe (do not have cost $79 each)





Laboratory :

1. Determination of the formula of a compound. (1.5hs)a
crucible with cover, crucible tongs. triangle, ring stand, bunsen burner, filter paper, 125ml Erylmeyer flask, funnel

2. Determination of the percentage of water in a hydrate (1hr)(a)
crucible with cover, crucible tongs. triangle, ring stand, bunsen burner, filter paper, 125ml Erylmeyer flask, funnel

3. Determination of molar mass by vapor density (1.5hr)(b)
large test tube (13X100mm) and one hole cork, thermometer, 400ml beaker, hot plate
4. Determination of molar mass by freezing-point depression (2hr)(a)
Vernier temp probe, ring stand, utility clamp, 400ml beaker, largest test tube (18X150mm)

5. Determination of molar volume of a gas. (2hr)(a)
Vernier temp probe, Vernier pressure probe (plastic tube with two Luer-lock connectors and rubber stopper assembly with two-way valve), 20ml gas syringe, 600ml beaker, 125ml Erlenmeyer flask

6. Standardization of a solution using primary standard (2hr)(a)
Vernier pH probe, 50ml buret, 50ml graduated cylinder, 250ml beaker, disposable pipet (10ml)

7. Determination of concentration by acid-base titration, including weak acid or weak base (2hr)a,b
Vernier pH probe, 50ml buret, 50ml graduated cylinder, 250ml beaker, disposable pipet (10ml)

8. Determination of concentration by oxidation-reduction titration (2hr)c
25ml volumetric flask, 50ml buret, 250ml Erlenmeyer flask

9. Determination of mass and mole relationship in a chemical reaction (2hr)a
Vernier temp probe, 10ml graduated cylinder, 25ml graduated cylinder, 50ml graduated cylinder, 250ml beaker

10. Determination of the equilibrium constant for a chemical reaction (2hr)a
Vernier colorimeter, 50ml volumetric flasks, 10ml disposable pipets, small test tubes (20X150mm), 100ml beakers

11. Determination of appropriate indicators for various acid-base titration, pH determination (2hr)a
Vernier pH probe, 250ml beaker, 50ml graduated cylinder, ring stand, buret clamp, 50ml buret

12. Determination of the rate of a reaction and its order. (2hr)c
50ml Erlenmeyer flask, 10ml graduated cylinder, one-hole stopper attachment (see c for details)

13. Determination of enthalpy change associated with a reaction (2hr)a
25ml graduated cylinder, beaker, styrofoam cups, thermometer

14. Separation and qualitative analysis of cations and anions. (3+hr)b
test tubes, small (13X100mm), 10ml disposable pipets, pH paper

15. Synthesis of a coordination compound and its chemical analysis (2+hr)(b)
??????

16. Analytical gravimetric determination (1.5hr)(a,b)
????
17. Colorimetric or spectrophotometric analysis (2hr)(b)

18. Separation by chromatography (2hr)( b,c)

19. Preparation and properties of buffer solutions (1.5hr)b

20. Determination of electrochemical series (1hr)(a,b)

21. Measurement using electrochemical cells and electroplating (1.5hr)(a, c)

22. Sythnesis, purification and analysis of an organic compound (2+hr)(b)
test tube small (13X100mm), 250ml beaker, 400ml beaker, hot plate


ApchemWiki | RecentChanges | Preferences
Edit text of this page | View other revisions
Last edited July 16, 2007 8:57 pm (diff)
Search: