List Of Labs - Equipment Ordering

ApchemWiki | RecentChanges | Preferences

Showing revision 9
Laboratory Manual:

We do not use one specific lab manual but rather a collection from various sources including:
a. Randall, Jack , Advanced Chemistry with Vernier, Vernier Software & Technology, (ISBN 1-929075-36-7 (alternate, search)).
b. Vonderbrink, Sally Ann, Laboratory Experiments for Advanced Placement Chemistry, (ISBN 1-877991-34-1 (alternate, search)).
c. Fossett, Martin and Hostage, David, AP Chemistry Laboratory Investigations.


General List

Glassware
1. 50ml buret
4. 125ml Erylmeyer flask
3. 250ml beakers
5. 400ml beakers
6. 600ml beaker
6. 50ml graduated cylinders
7. Test tubes, large (13X100mm)
8. Test tubes, larger (18X150mm)

Disposable
5. filter paper
6. 10ml disposable pipets

Short term use equipment
2. crucible with cover
6. funnel
9. Thermometer

Long term use equipment
1. bunsen burner
3. crucible tongs
7. One hole cork for large brtest tubes
7. Ring stands
7. O rings
8. utility clamp
8. Triangle
9. Hot plates

Vernier Probes
1. Temp probe
2. pH probes
2. Gas pressure probe (plastic tube with two Luer-lock connectors and rubber stopper assembly with two-way valve)
3. 20ml gas syringe



Laboratory :
1. Determination of the formula of a compound. (1.5hs)a
crucible with cover, crucible tongs. triangle, ring stand, bunsen burner, filter paper, 125ml Erylmeyer flask, funnel

2. Determination of the percentage of water in a hydrate (1hr)(a)
crucible with cover, crucible tongs. triangle, ring stand, bunsen burner, filter paper, 125ml Erylmeyer flask, funnel

3. Determination of molar mass by vapor density (1.5hr)(b)
large test tube (13X100mm) and one hole cork, thermometer, 400ml beaker, hot plate
4. Determination of molar mass by freezing-point depression (2hr)(a)
Vernier temp probe, ring stand, utility clamp, 400ml beaker, largest test tube (18X150mm)

5. Determination of molar volume of a gas. (2hr)(a)
Vernier temp probe, Vernier pressure probe (plastic tube with two Luer-lock connectors and rubber stopper assembly with two-way valve), 20ml gas syringe, 600ml beaker, 125ml Erlenmeyer flask

6. Standardization of a solution using primary standard (2hr)(a)
Vernier pH probe, 50ml buret, 50ml graduated cylinder, 250ml beaker, disposable pipet (10ml)

7. Determination of concentration by acid-base titration, including weak acid or weak base (2hr)(a,b)
8. Determination of concentration by oxidation-reduction titration (2hr)( c)
9. Determination of mass and mole relationship in a chemical reaction (2hr)(a)
10. Determination of the equilibrium constant for a chemical reaction (2hr)(a,b)
11. Determination of appropriate indicators for various acid-base titration, pH determination (2hr)(a)
12. Determination of the rate of a reaction and its order. (2hr)( c)
13. Determination of enthalpy change associated with a reaction (2hr)( a)
14. Separation and qualitative analysis of cations and anions. (3+hr)(b)
15. Synthesis of a coordination compound and its chemical analysis (2+hr)(b)
16. Analytical gravimetric determination (1.5hr)(a,b)
17. Colorimetric or spectrophotometric analysis (2hr)(b)
18. Separation by chromatography (2hr)( b,c)
19. Preparation and properties of buffer solutions (1.5hr)( b)
20. Determination of electrochemical series (1hr)(a,b)
21. Measurement using electrochemical cells and electroplating (1.5hr)(a, c)
22. Sythesis, purification and analysis of an organic compound (2+hr)(b)


ApchemWiki | RecentChanges | Preferences
Edit revision 9 of this page | View other revisions | View current revision
Edited July 16, 2007 2:53 pm (diff)
Search: